Inspection And Repair Of Screw Support Bearing Clearance
Leave a message
For example, the dial indicator for measuring the lead screw does not swing when the lead screw rotates forward and reverse, indicating that the lead screw does not move. If the pointer of the dial indicator swings, it means that the lead screw is moving. The difference between the maximum and minimum measurement values of the dial indicator is the distance of the axial movement of the screw. At this time, we need to check whether the back cap of the support bearing is locked, whether the support bearing has been worn out, and whether the preloaded bearing washer is suitable. If there is no problem with the bearing, simply reconfigure the preload washer. If the bearing is damaged, it is necessary to replace the bearing, reconfigure it as a preload washer, and then tighten the back cap. The axial movement of the lead screw mainly depends on the accuracy of the preload washer of the support bearing. The most ideal state of screw installation accuracy is that there is no positive and negative clearance, and the support bearing should have an interference of about 0.02mm.